NewTom VGi - Vertical Patient CB3D Scanner

- NewTom VGi "professional-grade" CB3D scanner
- Exclusive Safe BeamTM technology sets the radiation level automatically through the evaluation of the patient's anatomical density. A small child receives up to 40% less radiation than the already very low level for a full-sized adult.
- Safe BeamTM technology automatically and continuously monitors system operations eliminating the possibility of incorrect exposures
- The first 3D scanner unit to capture both high resolution images and large volume functionality in a single machine
- Obtain resolutions down to a .075mm voxel, or acquire a large 15cm x15cm field of view scan when needed
- 7 FOV's with 4 separate possible voxel sizes
- Image taken at every degree of rotation. 360° rotation = 360 images, increasing the range of possibilities for image manipulation
- Small footprint and flexible seating make the NewTom VGi the practical choice for offices where space is at a premium
- Revolutionary flat panel x-ray detector technology and small focal spot, produce the clearest, sharpest images possible
- Patient positioning tools include cross-hair lasers and a mirror – powerful tools for exact horizontal and vertical patient positioning
- Image reconstruction at approximately 1 minute, which translates into less down time for the dental team
- Single computer terminal and economical data storage

- With much less radiation than most other cone-beam systems, and up to 20 - 50 times less radiation than conventional CT, the NewTom VGi scanner uses a unique "pulse" system that unlike other systems, activates the x-ray source only when needed
| NewTom VGi | |||
| X-ray source | High frequency, constant potential (DC), rotating anode: 110 kV; 1-20 mA (pulsed mode) | ||
| Focal spot | 0.3 mm (IEC 60336) | ||
| X-ray cone beam | Proprietary Safe Beam™ control reduces radiation based on patient size | ||
| Dose | 100 μSv (ICRP 2007, estimate for adult) | ||
| Image acquisition | 360 images - 360 degree rotation | ||
| Image detector | Amorphous silicon flat panel, 20 cm x 25 cm (Field of View) | ||
| Signal gray scale | 14 bit | ||
| Scan time | 18 seconds in standard resolution mode | ||
| Patient position | Standing or seated and wheelchair accessible | ||
| Reconstruction time | Approximately 1 minute | ||
| Image storage | DICOM 3.0, CD/DVD. local network, printer (optional)* | ||
| Weight | Scanner unit: 600 lb (272 kg), Control box: 220 lb (100 kg) | ||
| Power required | 10A @ 100/115V~, 5A @ 200/215/230/240V~, 50/60Hz | ||
| Software | NNT™ with free viewer and sharing application | ||
|
|
Voxel Size Options | |||||
|
|
Height |
Diameter |
||||
|
Standard Resolution Scanning Mode |
15 cm |
15 cm |
.30 mm |
.25 mm |
.20 mm |
.150 mm |
|
12 cm |
15 cm |
.30 mm |
.25 mm |
.20 mm |
.150 mm |
|
|
8 cm |
12 cm |
.30 mm |
.25 mm |
.20 mm |
.150 mm |
|
|
8 cm |
8 cm |
.30 mm |
.25 mm |
.20 mm |
.150 mm |
|
|
HIRes Scanning Mode |
8 cm |
12 cm |
.15 mm |
.125 mm |
.100 mm |
.075 mm |
|
8 cm |
8 cm |
.15 mm |
.125 mm |
.100 mm |
.075 mm |
|
|
6 cm |
6 cm |
.15 mm |
.125 mm |
.100 mm |
.075 mm |
|
Specifications subject to change without prior notice.